Home  /  Blog  /  Decking joist spacing

Decking joist spacing: a practical UK guide

Set out a stronger deck from the start. Understand joist centres, compare timber and composite guidance, and plan the extra support that angled boards need.

London Decking Specialists team · 13 November 2026

Composite decking boards being installed over regularly spaced timber joists

What spacing should decking joists be?

Many domestic decking products use joists at 300–400mm centres, but there is no single spacing for every board. Choose the exact board first, then follow its installation guide for the material, layout and intended use. Some thicker timber products allow wider centres; diagonal layouts often need closer support.

The numbers below refer to the joists beneath the boards. They are different from the gaps between decking boards, and from the distance a joist can span between beams or posts.

Anatomy of a deck: what are the parts called?

Deck boards form the surface. The joists underneath support them, while the rim joist closes off the joist ends. The outer side joists complete the perimeter frame. Fascia is the finishing cover around that frame, rather than a substitute for a structural timber.

Decking anatomy showing boards, joists, rim joist, noggins, joist bays, fascia and supporting beams
A joist bay is the space between neighbouring joists. The side view shows how beams and posts can support the frame; actual construction details vary.
Diagram showing decking joist centres measured from the middle of one joist to the next
Measure centre to centre, rather than the empty space between timbers.

Decking joist centres: what are you measuring?

A specification of 400mm centres means 400mm from the middle of one joist to the middle of the next.

With joists that actually measure 47mm wide, that leaves a clear gap of 353mm. Leaving a 400mm clear gap would create 447mm centres, exceeding a 400mm limit.

You can also measure from the same edge of one joist to the same edge of the next, provided both joists are the same width.

Timber and composite decking joist spacing UK: manufacturer comparison

These selected product examples and supplier guides show why the board specification matters. Dimensions are in millimetres. Straight-laid boards run at 90° to the joists. Follow the linked guide for the complete installation detail.

Manufacturer / productStraight-laid centresDiagonal / 45° layoutConditions to check
Wickes timber decking: general laying guide400 centres; do not exceedNot specified in this guideGeneral timber-deck installation guidance, not a product-specific span rating for every Wickes board. Confirm the exact board and layout.
GripDeck softwood, 28 × 145400Confirm closer centresProduct guidance; check grade, load and fixings.
GripDeck softwood, 34 or 45 × 145Up to 500Confirm closer centresNot a general allowance for all thick timber boards.
Dino Decking composite boards300 maximumConfirm the angle-specific detailDino’s guide specifies no more than 300mm centres and separate support and fasteners for each board end at butt joints.
Hyperion Pioneer / Explorer (EnviroBuild)300 maximum250 diagonal maximumUse double joists at board-end joints. Check the complete guide for your chosen pattern.
Hyperion Frontier (EnviroBuild)400 maximum300 diagonal maximumFrontier allows different centres from Pioneer and Explorer.
Ultra Decking composite, residential guidance300 maximum250 diagonalThe guide also specifies 250mm for commercial use. Confirm the current instructions for the selected board.
Millboard, normal residential use400 maximum300 maximumSteps: 300 at 90°. Each board needs at least three joists.
Cladco Signature composite400 maximumUse guide’s angle detailBoard ends fully supported; use the specified clip system.
Cladco ProDeck / VersaDeck300 maximumUse guide’s angle detailCapped composite has different instructions from Signature.
Cladco Nordeck PVC300 recommendedConfirm with supplierPlan double joists at board-end joints.

Manufacturer guidance checked 13 November 2026. This is a product comparison, not a structural span table. Where a guide describes diagonal spacing without naming an angle in its table, confirm the intended layout. A blank numerical angle recommendation is not permission to use the straight-laid spacing.

Why “composite” is not a spacing specification

Different board profiles and materials behave differently. Even ranges from the same supplier can need different support. The table shows 400mm for Cladco Signature and 300mm for ProDeck / VersaDeck. Dino specifies a maximum of 300mm; Hyperion Explorer and Frontier also have different limits. Confirm the range name before setting out the frame.

For timber, finished thickness is only part of the decision. Species, grade and the board profile also matter. See our decking board thickness guide before ordering.

Joist spacing for diagonal decking and angled layouts

A diagonal board travels further between the same two joists. At 45°, joists set 400mm apart create a distance of about 566mm along the board between centre-line crossings.

That is why rotating the boards without changing the frame can leave them under-supported. Millboard’s residential guidance, for example, changes from 400mm at 90° to 300mm at 45°.

An alternative is to rotate the joists too, so that the boards still cross them at 90°. That changes the frame design and needs planning around the supporting beams.

Diagram showing how a 45-degree board crosses 400mm deck joist spacing over approximately 566mm
The illustration explains the geometry; it is not an approved spacing for a particular board.

What changes at 30°, 45° and 60°?

The table below keeps the same 400mm distance along the board between joist centre lines. Angles are measured between the board and the joist, so 90° means straight across. These are calculated geometry examples, not installation recommendations.

Board-to-joist angleCalculated joist centres
90°400mm
60°346mm
45°283mm
30°200mm

Calculation: centres = 400 × sin(angle). Use the manufacturer’s tested layout requirements when specifying the actual deck.

Herringbone, chevrons and picture-frame borders

Closer regular joists alone do not support every short or mitred board end. Draw the pattern over the frame plan and mark each joint. Add the supports and fixing space required for the chosen system, including around breaker boards and borders.

A picture-frame board can run parallel to the main joists. It needs its own support arrangement, rather than relying on the last joist beneath the main field of boards.

Decking joist size and unsupported span are separate checks

Joist spacing controls the support beneath the deck boards. The unsupported span controls how far the joist itself runs between its bearings.

Two decks can both have 400mm joist centres while needing very different joist sizes. A low deck with frequent support points is different from a raised deck where the joists bridge a longer distance.

Do not choose a joist size from the spacing number alone. Specify the timber grade or proprietary frame system, actual section size, bearing positions, loads and connections together. Raised decks, heavy planters and hot tubs need a frame designed for their particular loads.

Timber garden decking with a broad step and finished fascia concealing the outer frame
The outer edge has two roles: the frame supports the boards, and the fascia gives it a finished face. Steps need their own support detail.

How to set out spacing for decking joists

  1. Choose the boards and pattern. Record the exact product, finished size and permitted centres.
  2. Plan all board ends. Locate joints, borders and changes in direction before marking regular joists.
  3. Check the frame supports. Confirm joist sizes, bearings and connections separately from board spacing.
  4. Mark both sides of the frame. Use centre-line marks and check the frame is square before fixing.
  5. Divide the remaining bays evenly. Round the number of bays up so none exceeds the permitted centres.
  6. Recheck before covering. Measure the widest bay and confirm support and fixing access at every end.

Worked example: a 3m centre-line distance

If the first and last joist centre lines are 3,000mm apart and the maximum centres are 400mm:

3,000 ÷ 400 = 7.5 → use 8 bays.
3,000 ÷ 8 = 375mm centres.
8 bays require 9 joist lines.

This includes the two boundary joist lines. Board joints, borders and other details may require more. Measure between centre lines, not simply the outside dimensions of the finished deck.

Use our decking calculator for a starting materials estimate. It does not design the structure or calculate diagonal and herringbone layouts.

Grey composite decking forming a narrow garden path and wider seating area
Plan the frame around changes in width, borders and the direction of the boards.

Plan awkward edges before building the frame

Garden paths, narrow returns and planting cut-outs can leave short board sections and unusual fixing positions. A regular joist grid is only the starting point.

Draw each change of direction and identify where every cut end will finish. Check that the frame provides enough bearing and space for the specified fixings, especially where a narrow board meets a border.

For a new installation or complete replacement, our London decking fitters can help plan the surface and supporting frame together.

Deck joist spacing: common questions

Can I use 600mm joist centres?

Only if the exact board specification and project design allow it. Do not transfer a floor-joist spacing rule to an outdoor deck, or assume all thicker boards can span 600mm.

Can I fit composite boards onto an existing timber frame?

Check the frame’s condition, level, joist spacing and support arrangement against the new board guide. A frame that suited the previous boards may need additional joists or complete replacement.

Are noggins a substitute for closer joists?

Regular blocking can restrain joist movement, but does not automatically reduce the span of each deck board. Additional support must actually sit beneath the relevant board and meet the fixing detail.

Is decking joint spacing the same as joist spacing?

No. Joint spacing usually means the gap between boards or board ends. Those gaps allow for movement and drainage. Joist spacing describes the supporting frame underneath. Follow the board guide for both.

Should board ends share one joist?

Follow the board and fixing system’s detail. Both ends need adequate bearing and fixing clearance; some systems require double joists so each end has its own support and clip.

Sources and installation guides

Read the current guide for your exact product before construction. Figures above cover selected support-spacing details, not every requirement for a complete installation.

Images are illustrative. Joist-centres and diagonal-layout diagrams are reused from our thickness guide.

A well-planned frame makes a better deck

Planning a new deck or a complete replacement in London? Our team can assess your garden, discuss the board layout and quote for the installation.

Arrange a free decking quote